Use the values pulled from module and inverter spec sheets Module: Pmax = 257 W, Voc 38.2 V, Isc= 8.4 A, Vmp 30.2 V, Imp= 8.1 A Inverter: Turn on voltage: 160 V, Maximum Input Current: 18 A, Maximum input voltage: 600 V, MPP Voltage Range: 120-480, Maximum number of strings: 3 Ann Arbor, MI- Record low temperature: -30ºC, Average High: 28ºC What is the minimum number of modules in series that will work with this inverter? Reply
Use the values pulled from module and inverter spec sheets
Module: Pmax = 257 W, Voc 38.2 V, Isc= 8.4 A, Vmp 30.2 V, Imp= 8.1 A
Inverter: Turn on voltage: 160 V, Maximum Input Current: 18 A, Maximum input voltage: 600 V, MPP Voltage Range: 120-480, Maximum number of strings: 3
Ann Arbor, MI- Record low temperature: -30ºC, Average High: 28ºC
What is the minimum number of modules in series that will work with this inverter?